高频接触物体表面清洁质量的调查
作者:
作者单位:

作者简介:

罗盛鸿

通讯作者:

中图分类号:

R181.3+2

基金项目:


Cleaning quality of frequently touched object surfaces
Author:
Affiliation:

Fund Project:

  • 摘要
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 文章评论
    摘要:

    目的了解某院高频接触物体表面清洁质量,以制订有效的循证干预措施。方法2014年10月—2015年2月应用荧光胶剂对该院普通病房、手术室、重症监护病房(ICU)高频接触物体表面进行标记,每周1~2次,于患者出院前、手术结束后进行标记,清洁后检查物体表面清洁质量。结果共监测物体表面2 131处,清除1 732处,清除率为81.3%,卫生清洁质量处于合格状态。普通病区监测642处,清除率达82.1%;手术室监测650处,清除率75.8%;ICU区监测839处,清除率84.9%,3个病区物体表面清除率比较,差异有统计学意义(χ2 =19.964,P<0.001)。普通病区呼叫按钮、电开关和设备带清除率分别是51.3%、55.2%和58.5%,手术室墙和麻醉机控板、摇床器、键盘和输液泵的卫生清除率分别是38.6%、48.8%、60.0%、61.3%、68.4%,ICU设备带的清除率为65.9%,均处于不合格状态。结论该院环境卫生清洁质量总体处于合格状态,但仍有需要改进的地方,该院高频接触物体表面的清洁质量有待进一步提高。

    Abstract:

    ObjectiveTo investigate the cleaning quality of  frequently touched object surfaces in a hospital, so as to formulate effective evidencebased intervention measures.MethodsFrequently touched object surfaces in common wards, operating rooms, and intensive care unit(ICU) of the hospital between October 2014 and February 2015 were labeled by fluorescent adhesive agents 1-2 times a week, objects were labeled before patients’ discharge and at the end of operation, cleaning quality of frequently touched object surfaces were checked after routine cleaning.ResultsA total of 2 131 object surfaces were monitored, fluorescent adhesive agents on 1 732 objects were cleared, clearance rate was 81.3%,hygienic clean was qualified. 642,650,and 839 objects surfaces in common wards, operating rooms, and ICU were monitored respectively, the clearance rates were 82.1%,75.8%,and 84.9% respectively,  the clearance rates  among three wards were significantly different (χ2 =19.964,P<0.001). In common wards, fluorescent clearance rates of call buttons, power switches, and equipments were 51.3%,55.2%, and 58.5% respectively; in operating room,  fluorescent clearance rates of room wall, control panel of anesthesia machine, bedadjusting device, keyboards, and infusion pumps were 38.6%,48.8%,60.0%,61.3%,and 68.4%,respectively; in ICU, fluorescent clearance rates of equipments was 65.9%, all were unqualified.ConclusionThe environmental hygiene quality is generally qualified in this hospital, but the cleaning quality of frequently touched object surfaces needs to be further improved.

    参考文献
    相似文献
引用本文

罗盛鸿,左亚沙.高频接触物体表面清洁质量的调查[J]. 中国感染控制杂志,2016,15(7):515-517. DOI:10.3969/j. issn.1671-9638.2016.07.019.
LUO Shenghong, ZUO Yasha. Cleaning quality of frequently touched object surfaces[J]. Chin J Infect Control, 2016,15(7):515-517. DOI:10.3969/j. issn.1671-9638.2016.07.019.

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2015-10-05
  • 最后修改日期:2016-01-23
  • 录用日期:
  • 在线发布日期: 2016-07-30
  • 出版日期: