Abstract:ObjectiveTo monitor the quality of inuse disinfectant,evaluate the causes of exceeding of bacterial content standard, and put forward the corresponding management measures. MethodsAccording to the different management methods, disinfectant specimens were divided into experimental group(n=210, from August 2012 to July 2013) and control group (n=190, from August 2011 to July 2012); inuse disinfectant in experimental group was contained with groundglass stoppered bottles, inuse disinfectant in control group was contained with stainless bottles and groundglass stoppered bottles, biological monitor results of two groups were compared. ResultsQualified rate of biological monitor result in experimental group was 100.00%(201/201),and in control group was 90.00%(171/190), there was significant difference between two groups(χ2=21.13,P<0.05).ConclusionImproving management method can increase the qualified rate of biological monitoring result of inuse disinfectant, and ensure the safety and effectiveness of disinfection.